HOME„Melt Quality Control >Molten metal controlling device at furnace / QCR-1000 / QCR-2000

Molten metal controlling device at furnace ( CE - meter )QCR-1000 / QCR-2000

(This product is not for sale)
  • Thermal analysis to obtain CE value, C%, and Si%
  • List of result of a measurement indication of the dayI
  • nitial charge calculation,recharge calculation, etc
  • Data saving and reviewing possible.
  • Keyboard: malfunction prevention function.

 

Measuring CE value and calculating C% and Si%

Turn on power. After the measurement screen is displayed, place a cup on the holder and pour molten metal into the cup.

As measuring starts, the cooling curve will be shown on the screen. Detecting the primary crystal temperature, tensile strength and CE value are displayed.

The detected eutecitic temperature is displayed, then C% and Si% are calculated to complete measuring.

Display

List of measured data

Variation chart of primary crystal temperature and eutecitic temperature.

Variation chart of CE, C%, Si%

Specification(This product is not for sale)

Type

QCR-1000

QCR-2000
Dimensions (mm) H270 × W230 × D80 H350 × W310 × D80
Monitor (inch) 7.5 12
Weight (kg)
3.0 5.5
Measurement range 0 - 2400°F (JIS-K)
Operation procedure Designed keyboard ( built in the body )
Measuring Accuracy
  • CE : 2.30`4.80 :±0.05
  • C% : 2.50`4.00 :±0.03
  • Si%: 0.05`3.50 :±0.06
Accompanied parts
  • Cup stand (cable length: 5m)
  • Pedestal

option

Please contact us for more details.

  • Printer
  • The monitor distribution outputiVGAj
  • Data communication of the result of a measurement
  • Wired thermometer add

Corresponding consumables

Related product

Download
@@@@@
Contact Us